Rooftop solar · the register

Is it on the register?

4,606 rooftop solar PV devices that have been through a type test, from the Energy Networks Association’s Connect Direct register. Search it by manufacturer, by the model number on the label, or by system reference — and every device has its own page and its own URL, which the ENA’s own search does not.

4,606 of 4,606 PV devices
ManufacturerModelSystem referenceRegistered capacityPhasesG98 (GB)Published
Growatt New Energy Technology LimitedSPA 10000TL3 BHGROWA/04631/V110 kW32625 Apr 2022
Growatt New Energy Technology LimitedSPH3000TL BL-UPGROWA/04560/V13 kW1024 Apr 2022
Growatt New Energy Technology LimitedSPH 3600TL BL-UPGROWA/04561/V13.6 kW1024 Apr 2022
Growatt New Energy Technology LimitedSPH 4000TL BL-UPGROWA/04562/V14 kW1024 Apr 2022
Growatt New Energy Technology LimitedSPH 4600TL BL-UPGROWA/04563/V14.6 kW1024 Apr 2022
Growatt New Energy Technology LimitedSPH 5000TL BL-UPGROWA/04569/V15 kW1024 Apr 2022
Growatt New Energy Technology LimitedSPH 6000TL BL-UPGROWA/04570/V16 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 4200TL-XHGROWA/04571/V14.2 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 4600TL-XHGROWA/04572/V14.6 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 5000TL-XHGROWA/04573/V15 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 6000TL-XHGROWA/04574/V16 kW1024 Apr 2022
Growatt New Energy Technology LimitedMOD 3000TL3-XHGROWA/04578/V13 kW3024 Apr 2022
Growatt New Energy Technology LimitedMOD 4000TL3-XHGROWA/04579/V14 kW3024 Apr 2022
Growatt New Energy Technology LimitedMOD 5000TL3-XHGROWA/04580/V15 kW3024 Apr 2022
Growatt New Energy Technology LimitedMOD 6000TL3-XHGROWA/04581/V16 kW3024 Apr 2022
Growatt New Energy Technology LimitedMOD 8000TL3-XHGROWA/04584/V18 kW3024 Apr 2022
Growatt New Energy Technology LimitedMOD 9000TL3-XHGROWA/04585/V19 kW3024 Apr 2022
Growatt New Energy Technology LimitedMOD 10000TL3-XHGROWA/04586/V110 kW3024 Apr 2022
Growatt New Energy Technology LimitedMIC 750TL-XGROWA/04587/V10.75 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIC 1000TL-XGROWA/04588/V11 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIC 1500TL-XGROWA/04589/V1/A11.5 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIC 2000TL-XGROWA/04590/V12 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIC 2500TL-XGROWA/04595/V12.5 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIC 3000TL-XGROWA/04597/V13 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIC 3300TL-XGROWA/04598/V13.3 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 2500TL-XAGROWA/04599/V12.5 kW12624 Apr 2022
Growatt New Energy Technology LimitedMIN 3000TL-XAGROWA/04600/V13 kW12624 Apr 2022
Growatt New Energy Technology LimitedMIN 3600TL-XAGROWA/04601/V13.6 kW12624 Apr 2022
Growatt New Energy Technology LimitedMIN 4200TL-XAGROWA/04602/V14.2 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 4600TL-XAGROWA/04603/V14.6 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 5000TL-XAGROWA/04604/V15 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 6000TL-XAGROWA/04605/V16 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 4200TL-XHGROWA/04606/V14.2 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 4600TL-XHGROWA/04607/V14.6 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 5000TL-XHGROWA/04608/V15 kW1024 Apr 2022
Growatt New Energy Technology LimitedMIN 6000TL-XHGROWA/04609/V16 kW1024 Apr 2022
Growatt New Energy Technology LimitedMOD 3000TL3-XHGROWA/04614/V13 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 4000TL3-XHGROWA/04615/V14 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 5000TL3-XHGROWA/04616/V15 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 6000TL3-XHGROWA/04617/V16 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 7000TL3-XHGROWA/04618/V17 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 8000TL3-XHGROWA/04619/V18 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 9000TL3-XHGROWA/04620/V19 kW32624 Apr 2022
Growatt New Energy Technology LimitedMOD 10000TL3-XHGROWA/04621/V110 kW32624 Apr 2022
Solis (Ginlong) (previously Ningbo Ginlong)S5-GC25KSOLIS/04225/V1/A325 kW3024 Apr 2022
Solis (Ginlong) (previously Ningbo Ginlong)S5-GC30KSOLIS/04232/V1/A430 kW3024 Apr 2022
Solis (Ginlong) (previously Ningbo Ginlong)S5-GC36KSOLIS/04233/V1/A436 kW3024 Apr 2022
Solis (Ginlong) (previously Ningbo Ginlong)S5-GC40KSOLIS/04234/V1/A340 kW3024 Apr 2022
Growatt New Energy Technology LimitedMAX 125KTL3-X LVGROWA/04502/V1125 kW3019 Apr 2022
Growatt New Energy Technology LimitedMAX 120KTL3-X LVGROWA/04503/V1120 kW3019 Apr 2022

On a narrow screen the table scrolls sideways inside its own box — the page itself never does.

What being on this register means. The inverter or PV device has been type tested against G98 or G99 — the engineering rules for generating alongside the grid, including the anti-islanding test.

What it does not mean. This register covers the equipment. It is not the MCS product register and it is not the MCS installer register, and it is MCS certification — not this — that a supplier asks for before paying you a Smart Export Guarantee tariff.

Absence is not a finding. Manufacturers register under their legal name and an internal model code, and both routinely differ from the name on the retail box — “TSUNESS Co., Ltd” and “TSOL-ESK800-U” are not what a shop calls them. If you cannot find your equipment here, the most likely explanation is that it is listed under a name you have not tried.

What we do not publish. The register carries a status field. We do not repeat it, anywhere, for any device. We have asked the Energy Networks Association what its values actually mean and have not had an answer, and every plug-in solar device on the register — including all eleven currently marked as not compliant — shows a completed full G98 type test. Printing a word we cannot explain, against the name of a real manufacturer, thousands of times over, is not something we are prepared to do. Follow the link on any device page and read the ENA’s own entry.

Source: ENA Connect Direct type test register, Energy Networks Association. We mirror it daily and record what changes; we never edit it.